Appendices TS790+ & TS900+ Installation Manual
Figure 30. Alarm Abort & Sequential Confirmation
1. If a plug-on digicom is being used program
the digicom channels as shown below, see
“Digicom Channels”, on page 25. If a stand-
alone digicom is being used program the
digicom outputs as shown below, see
“Digicom Outputs”, on page 25.
3 005 (Alarm)
7 071 (Abort)
8 011 (Second Alarm)
3. Program the “Abort Delay” timer to the
required time (the default is 180 seconds),
see “System Timers”, on page 30.
4. Program the digicom channels so that they
report the required signals.
Text Editing Keys
When programming any text the keys on the
keypad function as shown below:
Figure 31. Text Editing Keys
Cursor Types
This is the normal text editing cursor. Use
the text editing keys as shown above.
This is the number cursor. Use the
numbered keys 0 - 9 to enter numeric
data.
Common Key Sequences
Character Key Sequence Character Key Sequence
A 1 U 5
B 1A V 5A
C 1AA W 5AA
D 2C X 5AAA
E 2 Y 5AAAA
F 2A Z 5AAAAA
G 2AA : 1CCCCCCC
H 3C ; 1CCCCCC
I 3 < 1CCCCC
J 3A = 1CCCC
K 3AA > 1CCC
L 3AAA ? 1CC
M 4CC @ 1C
N 4C ! 0A
O 4 " 0AA
P 4A # 0AAA
Q 4AA $ 0AAAA
R 4AAA % 0AAAAA
S 5CC & 0AAAAAA
T 5C
Setup New Users
The TS790+/TS900+ allows up to 31 users to
operate the alarm system, each user is
assigned a user type and a passcode. User 01
is the master user which has a default setting of
5678.
User Types
The following user types are available:
User 02-31 can be programmed as the type
"Master". If the installation company has
programmed the master user for full access, he
or she will have access to all user menus and
options. If the installation company has
programmed the master user for limited
access, he or she will NOT have access to "User
menu 2" options 6 and 8, and all of "User menu
3".
Users 02-31 can be programmed as the type
"Standard". This user type can only access "User
menu 1".
Users 02-31 can be programmed as the type
"Holiday". This user type allows the alarm system
to be set and unset, and access to ‘ User menu
1’. However, the passcode is automatically
deleted from the system when a master user
passcode is used to unset the alarm system.
Normally the master user would assign this
passcode type a temporary user whilst the they
are away on holiday etc.
Users 02-31 may be programmed as "Set Only".
This user type allows the alarm system to be set
and access to "User menu 1".