TS790+ & TS900+ Installation Manual Appendices
Appendices
Contact ID Extended Reporting
Contact ID extended reporting is a new format
which when used with the DC58 or DC58M can
be used to report circuit ID data, user ID etc. In
order to used this format the DC58/DC58M must
be plugged on to the control panel and must
also be programmed to report “Extended
Format” (refer to the instructions supplied with
the DC58/DC58M). The central station alarm
receiver must also be capable of receiving
“Contact ID extended Format”.
Contact ID Reporting takes the following format:
CCCC Q EEE GG ZZZ where:
Customer account number.
Event qualifier, where E = new event (1) and R
= restore (3).
Event code (see table below).
Always 00.
Circuit/Contact ID number reporting the alarm
(001-056), or user number (001-031) for
open/close reports. System status messages
(Mains Fail, Walk Test, etc.) contain zeros in the
ZZZ location.
Code Description
110 Fire alarm
120 Panic (PA Code) alarm
121 Duress alarm
122 Silent PA alarm
123 Audible PA alarm
130 *Intruder alarm
134 Entry alarm
135 24 Hour alarm
137 Equipment tamper alarm
139 Confirmed alarm
150 Auxiliary alarm
Code Description
301 Mains failure
302 Low system battery
305 System reset (on-site or factory)
309 Battery test failure
382 Node or Remote removed
401 Open / Close by user
406 Alarm cancelled
409 Open / Close by keyswitch
411 Call-back requested (Lineload)
412 Successful download access
413 Unsuccessful download access
465 Restore PA
570 Circuits omitted
572 24 Hour circuits omitted
573 Cct "Actively" omitted
627 Engineer program mode selected
628 Engineer program mode cancelled
Contact ID Event Codes
*Becomes CCT Tamper if Engineer menu 1.9
option 30 is set to "Tamper is Burg".
Resetting the Engineers passcode
If the installation engineer has inadvertently
changed the engineers passcode or the
passcode has been forgotten, the passcode
can be reset back to 1234 without losing any
other programmed data. This procedure can
only be used providing a user passcode is
available:
1. Ensure that the system is unset and a user
passcode is available.
2. Remove the cover from the control panel,
this will cause a "Panel Lid tamper" alarm.
3. Ask the user to enter their passcode to
silence the alarm.
4. Place the blade of a small screwdriver
between the pins labelled "FACTORY RESET".
A multi-tone sound indicates the engineers
passcode has been reset.
5. Replace the control panel cover. At the
remote keypad enter 1234. The display will
show “Engineers Menu 1". To change the
engineer’s passcode see ”Change
Passcode” on page 40.