
Setup New Users
The TS790/TS900 allows up to 31 users to operate
the alarm system, each user is assigned a user
type, passcode and ward access. User 001 is the
master user which has a default setting of 5678.
User Types
The following user types are available:
Master
User 02-31 can be programmed as the type
"Master". If the installation company has
programmed the master user for full access, he or
shewillhaveaccesstoallusermenusandoptions.
If the installation company has programmed the
master user for limited access, he or she will NOT
haveaccessto"Usermenu2"options6and8,and
all of "User menu 3".
Standard
Users 02-31 can be programmed as the type
"Standard". This user type can only access "User
menu 1".
Holiday
Users 02-31 can be programmed as the type
"Holiday". This user type allows the alarm system to
be set and unset, and access to `User menu 1'.
However, the passcode is automatically deleted
from the system when a master user passcode is
used to unset the alarm system. Normally the
master user would assign this passcode type a
temporary userwhilstthe they areawayon holiday
etc.
Set Only
Users 02-31 may be programmed as "Set Only".
Thisusertypeallowsthealarmsystemtobesetand
access to "User menu 1".
Reset Only
Users 02-31 may be programmed as "Reset Only".
This user type allows 24hr alarms to be reset and
access to "User menu 1" option 1 to 9.
Duress
Users 02-31 can be programmed as "Duress".
When thisusertype isentereda silent"Panic Alarm"
(i.e., Bell and sounders not triggered) is transmitted
to the central station via the telephone line and
remote signalling device (if fitted). The user will still
be able to set and unset the alarm system and
access "User menu 1".
+
All other user code types will generate a
"Duress" alarm if the passcode is entered
with the first two digits reversed (e.g., for a
standard passcode of 2580 enter 5280 to
generate a "Duress" alarm). If required, this
feature can be disabled by the installation
company or by making the first two digits of
the passcode the same.
PA Code
Users 02-31 can be programmed as "PA Code".
When this user type is entered a "Panic Alarm"' is
transmittedtothecentralstationviathe telephone
line and remote signalling device (if fitted). The
external sounder(s) and strobe light(s) are also
activated.
Access
Users 02-31 can be programmed as "Access".
When this user type is entered any output that is
programmedas `Access'willactivatefor apre-set
time. Normally this user type is used in conjunction
with anelectric door strikeconnectedto the alarm
system so that when the passcode is entered the
door strikeisoperated toallowtheuser accessinto
that area.
Full Set Group
Users 02-31 may be programmed as "Full Set
Group". This user type only allows the wards
assigned by the installation company or master
user to be set and unset. This user type does not
have access to any user menus.
Code Set Group A
Users 02-31 can be programmed as "Code Set
Group A". This user type only allows the wards
assigned by the installation company or master
user to be set and unset. This user type does not
have access to any user menus.
TS790 & TS900 Installation Manual Appendices
59
Komentarze do niniejszej Instrukcji