Appendices
Point ID Extended Reporting
Point ID extended reporting is a new format which
when used with the DC58 or DC58M can be used
toreportcircuitIDdata,userIDetc.Inordertoused
this format the DC58/DC58M must be plugged on
to the control panel and must also be
programmedtoreport“Extended Format”(referto
the instructions supplied with the DC58/DC58M).
The central station alarm receiver must also be
capable of receiving “Point ID extended Format”.
Point ID Reporting takes the following format:
CCCC Q EEE GG ZZZ where:
CCCC Customer account number.
Q Event qualifier, where E = new event (1)
and R = restore (3).
EEE Event code (see table below).
GG Always 00.
ZZZ Circuit/Point ID number reporting the
alarm (001-056), or user number
(001-031) for open/close reports. System
status messages (Mains Fail, Walk Test,
etc.) contain zeros in the ZZZ location.
Code Description
110 Fire alarm
120 Panic (PA Code) alarm
121 Duress alarm
122 Silent PA alarm
123 Audible PA alarm
130 Intruder alarm
134 Entry alarm
135 24 Hour alarm
137 Equipment tamper alarm
150 Auxiliary alarm
301 Mains failure
302 Low system battery
305 System reset (on-site or factory)
309 Battery test failure
382 Node or Remote removed
383 Circuit tamper
Code Description
401 Open / Close by user
406 Alarm cancelled
409 Open / Close by keyswitch
411 Call-back requested (Lineload)
412 Successful download access
413 Unsuccessful download access
570 Circuits omitted
572 24 Hour circuits omitted
601 Manual test trigger
602 Timed test call
607 Walk test mode selected
625 Date or time changed
627 Engineer program mode selected
628 Engineer program mode cancelled
382 Node or remote removed
Point ID Event Codes
Resetting the Engineers passcode
If the installation engineer has inadvertently
changed the engineers passcode or the
passcode has been forgotten, the passcode can
be reset back to 1234 without losing any other
programmed data. This procedure can only be
used providing a user passcode is available:
1. Ensure that the system is unset and a user
passcode is available.
2. Remove the cover from the control panel, this
will cause a "Panel Lid tamper" alarm.
3. Ask the user to enter their passcode to silence
the alarm.
4. Place the blade of a small screwdriver
between the pins labelled "FACTORY RESTART".
A multi-tone sound indicates the engineers
passcode has been reset.
5. Replace the control panel cover. At the
remote keypad enter 1234. The display will
show “Engineers Menu 1". To change the
engineer’s passcode see ”Change Engineer’s
Passcode on page 36.
TS790 & TS900 Installation Manual Appendices
51