No Type Function
00 Bell On Active when the external Bell trigger is activated.
01 Strobe Active when the Strobe trigger is activated.
02 SW12 Used to latch device s in an alarm. Active when the system is set.
03 D etector Reset Used to power devices which r equire power to be removed to reset them.
04 Walk Test Active when a Walk Test is in progress.
05 Alarm Active when intruder alarm is present.
06 PA Active when a PA alarm is present.
07 Fi re Active when a Fire alarm is present.
08 Set Active when the system is Set.
09 CodeAccepted Active for 10 seconds when any valid passcode is entered.
10 24 Hour Active when a 24 hour circuit is in alarm.
11 Second Alarm Active when a second circuit causes an alarm, use for ALARM CONFIRMATION.
12 Courtesy Light Active when an y keypad is in use.
13 Engr on Site Activewhentheengineer'spasscodeisentered untilaUserpasscodeisentered.
14 Ccts Omitted Active when circuits are omitted.
15 Auxiliary Active when a n Auxiliary circuit is in alarm.
16 Sndr Control Can be used as the 0V connection to an extension loudspeaker so that the
sounder is muted during keypa d entries. Only suitable for panel out puts 1 & 2.
17 Area Set A Active when area A is Set .
18 Area Set B Active w hen area B is Set.
19 Area Set C Active when area C i s Set.
20 Tamper Active when a Aux, or circuit t amper is triggered.
21 Line Fault Active when a digicom telephone line fault occurs.
22 Mains Off Active when mains power is removed.
23 Exit/Entry Active during exit and entry.
24 Test Fail Active when a circuit on Test is activated.
25 Fi rst Knock Active when a double knock is acti vated for the first time.
26 D C Failed Active if the digicom fails to communicate.(plug-on)
27 D C Successful Active when the digicom sends a message and it is a cknowledged. (plug_on)
28 D C Active Active while the dig icom is trigger ed.(plug-on)
29 Second Entry Active when the second entry timer is sta rted.
30 Entry Active when the system is set or part set and the entry route is in use.
31 Exit Active when the system exit procedure is started.
32 Part Set C fail Active when Part Set area C fails to set.
33 Part Set B fail Active when Part Set area B fails to set.
34 Part Set A fail Active when Part Set area A fails to set.
35 Part Set Active when ever the system is Part Set.
36 Area C Alarm Active when Area C Alarms.
37 Area B Alarm Active when Area B Alarms.
38 Area A Alarm Active when Area A Alarms.
39 D uress Alar m Active when a duress code is entered at a keypad.
40 - 55 Circuit mimic Will mimic (ac tive when circuit is active) circuits 1 to 16 respectively .
Ta ble 2. Prog rammable Output Functions