User Menu 4 Shunt Groups
User menu 4
Select option :-
SYSTEM OPEN
18:10 Sun 01 JAN
User menu 4
Shunt groups
Group 00< 0001
0001 0001 0001
6
ENT
ENTENT ENT ENT
? ? ? ?
Enter group 00 - 49
e.g. 20
Group 20< 0001
0001 0001 0001
ENT
to edit
Group 20 >0001
0001 0001 0001
Enter circuit No.
e.g. 2001
ENT
to accept
Group 20 >2001
0001 0001 0001
Repeat for other
circuits required
or
SYSTEM OPEN
18:10 Sun 01 JAN
ESC ESC ESC ESC ESC
The TS2500 alarm system has 50 shunt
groups, each group can have up to 4
circuits assigned to it. The group can then be
allocated to a user passcode (type "Shunt").
When the passcode is entered the selected
group of circuits are shunted (isolated).
When the passcode is re-entered, the
selected group of circuits are reinstated.
1. At the remote keypad enter your
passcode then press [ENT] four times to
2. Select user menu 4.
3. Press [6] followed by [ENT] to select the
shunt group options.
4. Enter the group number or use the [A]
and [C] keys to scroll up and down
through the groups.
5. When the display shows the required
group, press [ENT] to edit the assigned
circuits.
6. The cursor (>) will point at the first circuit
in the group. Enter the circuit number,
e.g. 2001. (0001 = No Circuit).
7. Press [ENT], the cursor (>) will move to the
next circuit. Repeat for remaining
circuits. If a circuit is not required in the
group set it to 0001.
8. Repeat steps3-6for other shunt groups
or press [ESC] five times to return the
9. system to its original state.
46
Przeglądanie stron 47