18014 Drg. No. 33:1939:00 Issue 01 Doc 01 April 97
Key Function Action LEDs On Off
1
Zone Types
Press [1] - [5] to toggle
LEDs on/off.
Press [0] to end
1
2
3
4
5
Z1 = Access
Z2 = Access
Z3 = Keyswitch
Z4 = Fire
Z5 = PA
Z1 = Alarm
Z2 = Alarm
Z3 = Alarm
Z4 = Alarm
Z5 = Alarm
2
View Log
Press [1] for newest event
Press [4] for oldest event
Zone LEDs that light have caused an alarm
3
Walk Test
Activate detectors.
Press [0] to end
When the zone is in alarm the panel will sound
and the relevant zone LED will light.
4
Exit Time
Press [1] to [4].
Press [0] to end
1
2
3
4
10 seconds
30 seconds
1 minute
2 minutes
5
Entry Time
Press [1] to [4].
Press [0] to end
1
2
3
4
10 seconds
30 seconds
1 minute
2 minutes
6
Bell Duration
Press [1] - [5].
Press [0] to end
1
2
3
4
5
90 seconds
3 minutes
10 minutes
20 minutes
Continuous
7
Change Engineer's
Passcode
Enter new passcode
twice
Zone LEDs 1 - 4 will light, as code is entered
each LED will go out one by one.
8
Remote Reset No. Enter reset number twice
Zone LEDs 1 - 3 will light, as code is entered
each LED will go out one by one.
9
System Options
Press [1] - [6] to toggle
LEDs on/off
Press [0] to end
1
2
3
4
5
F.Exit
Bell output = SAB
Set by Final Exit
Reset by Engineer
3 re-arms
Key = Home set
RST = SW12V
Bell output = SCB
Set by Timed Exit
Reset by User
1 re-arm
Key = Away set
RST = Det. Reset
HOME
Part set the system Leave via exit route
AWAY
Full set the system Leave via exit route
0
Return to unset
Engineer's Quick Reference Programming Chart
Cooper Security Ltd, Security House,
Vantage Point Business Village,
Mitcheldean, Gloucestershire,
GL17 0SZ. England
Product Support Tel: +44 (0)1594 545556
Available between;
08:15 and 17:00, Monday to Thursday.
08:15 and 12:45 Friday. Emergency service only
between 12:45 and 17:00 Friday.
Product Support Fax: +44 (0)1594 545401.
w
ww.coopersecurity.co.uk
Komentarze do niniejszej Instrukcji