Defining Part-Set buttons to Arm a Ward(s)
This method of defining the part set groups
requires you to think of the system in terms of
separate areas of protection (Wards), then
configuring the part set groups so that different
combinations of wards are set.
1. From the previous part-set requirements assign
the different physical areas to wards, e.g.:
Ward A: Downstairs perimeter detection
(Circuits 01,04, 05 & 06).
Ward B:
Ward C: Bedroom 2 (Circuit 09).
2. Using the above ward requirements create a
Table for assigning circuits to wards. Circuits
with no ticks are assigned to the “System Ward”:
Circuit Location Ward A Ward B Ward C
01 Front Door
02 Smoke Detector
03 Hall door to garage
04 Garage door
05 Garage back door
06 Kitchen door
07 Dinning room PIR
08 Lounge PIR
09 Bedroom 2 PIR
10 Landing PIR
3. From the above Table assign circuits 01-10 to
their relevant wards (see “Configure Wards” on
page 37).
4. Program the part set groups, see “Part set
Groups”, on page 43. This ensures that when
the user selects button A, B or C the system
arms the correct wards. When using this
method, the part set groups are programmed
as follows:
Part Set Group A: [ AB ]
Part Set Group B: [ ABC]
Part Set Group C: [ A ]
This method will only work correctly if
circuits are assigned only to one ward.
If a circuit is assigned to more than one
ward, it will only be armed when all the
wards its assigned to are set.
54
Appendices TS790 & TS900 Installation Manual