Program Zones (key
1
)
The TSD402 zones may be programmed so that they perform different functions. The zones
types are as follows:
Night (N) - Zones 1-5 may be programmed as a Night zone, this type of
zone will only generate a full alarm when activated during a set
condition. If during a full alarm condition the speech dialler Alarm
channel is programmed to report, it will activate and send the
Alarm message.
Access (A) - Zones 1 and 2 may be programmed as an Access zone, this
type of zone is automatically isolated during the entry/exit
procedure to allow a "walk through" route for the user. Once the
system is full set the Access circuit responds as a Night circuit. If
an Access zone is armed during a part-set (HOME) condition it
will start the entry timer if activated.
Key switch (S) - Zone 3 may be programmed as a Keyswitch zone, this type of
zone will set the system when active (zone open) and unset the
system when healthy (zone closed). The Keyswitch zone
functionality may be further programmed to either full set (AWAY)
or part-set (HOME) the system (see System Options).
Fire (F) - Zone 4 may be programmed as a Fire zone, this type of zone is
monitored at all times, when activated a distinctive internal
sounder tone is generated and the external sounder is pulsed. If
during a fire alarm condition the speech dialler Fire channel is
programmed to report, it activates and sends the Fire message.
P.A. (P) - Zone 5 may be programmed as a Personal Attack (P.A.) zone,
this type of zone is monitored at all times, when activated a full
alarm is generated. If during a PA alarm the speech dialler P.A.
channel is programmed to report, it will activate and send the
P.A. message.
Final Exit (E or A) - The Final Exit zone is the last detector that is activated when
leaving the protected premises and the first detector to be
activated when re-entering the protected premises. This zone
may programmed to respond as follows:
Exit (E) When programmed as Exit the Final Exit zone will
generate an interrupted tone when opened during the Exit
procedure.
Access (A) When programmed as Access the Final Exit zone
will remain silent when opened during the Exit procedure. The
feature is useful if a PIR is used for the Final Exit zone, as it will
normally be activated several times before leaving the building.
TSD402 Installation Manual Programming