Example 4. Foyer Mode
A building owner wants the control panel to arm the
reception area when the tenants have set all of wards
B,C,D,E,F. The first person into the building in the
morning is always the security guard who will only turn off
the reception area as he is not permitted to access the
offices.
Operation:
Assuming the system is fully set, at 7.00am the security
guard enters the reception area and enters his
passcode at the remote keypad in the reception area,
to unset ward A (Foyer). When the next user arrives they
enter their passcode into the keypad which unsets their
own office. This may continue until all offices are unset
by their respective users.
At 6.00pm the security guard leaves the premises. He
locks the main entrance but does not set the system
because one of the staff is working late in the one of the
offices. At 7.00pm the user now wishes to leave the
premises. They unlock the main entrance door and
enter their passcode at the remote keypad.
After leaving and securing the main entrance door the
system sets their ward and, because they are the last
user to set, also sets ward A (Foyer).
Note: Do not assign ward A itself to foyer mode, only the
rest of the wards. This means that only the outputs
allocated to ward A will trigger.
5
TS2500 Hints and Tips
C
CP
P
Key:
Control Panel
XN
Xnode
Magnetic Contact
Passive Infra-Red Detector
Remote Keypad
Users:
No Type Wards
001 Master A B C D E F
002 Standard Ward A (Security Guard)
003 Standard Ward B
004 Standard Ward C
005 Standard Ward D
006 Standard Ward E
00
7
Sta
n
da
r
d
W
a
r
d
F
CP
XN
XN
P
P
P
P
P
Office Area
Ward C
Ward C
Ward C
Ward D
Ward D
Ward E
Ward E
Ward F
Ward A
Ward B
Ward A
Ward A
Ward B
Ward F
Office Area
Ward D
Office Area
Ward E
Office Area
Ward F
Office Area
Ward B
Reception Area
Ward A
P
RK
C
C
C
C
C
CC
RK
Figure 3. Foyer Mode Example
Assign circuit types.
Enter User Menu 3.
Program Part set Groups.
Assign ward A to Part set Group 1.
Assign circuit attributes.
Allocate zones to wards.
Program system timers.
1 4
Program setting modes.
Program network equipment
to wards.
Program other equipment
to wards.
Assign detectors:
In reception to Ward A,
In each office to respective Ward.
Each ward must have its own exit and
entry delay time. In the example, ward
A and B have entry and exit times of
60s.
Each ward must have its own setting
mode.
Make sure that xnode are assigned
to wards C and E.
Assign keypad in reception to
ward A.
Make sure that tampers are assigned
to the correct nodes.
In the example the panel and bellbox
tamper are assigned to ward A.
Assign Wards B, C, D, E and F to
"Ward A Foyer Mode".
ENT
ENT
ENT ENT ENT
1 5
ENT
ENT
1 6
ENT
ENT
4 2
ENT
ENT
4 3
ENT
ENT
2
ENT
Enter Engineer's
Passcode
To: Notes:
Log Off Engineer Mode.
Log Off User Programming Mode.
Then key in:
To: Notes:
Then key in:
1234
Enter Master User's
Passcode
5678
Przeglądanie stron 4
1 2 3 4 5 6 7 8

Komentarze do niniejszej Instrukcji